- Nuts[10]
- Steel Round Bars[1]
- Steel Wire[2]
- Steel Structures[2]
- Scaffoldings[3]
- Metal Building Materials[3]
- Container[10]
- Prefab Houses[10]
- Other Metal Processing Machinery[5]
- Bending Machinery[2]
- Diesel Generators[1]
- Lathe[1]
- Tile Making Machinery[2]
- Console Tables[2]
- Living Room Cabinets[2]
- Wardrobes[2]
- Doors[1]
- Dining Tables[2]
- Tiles[4]
- Steel Strips[6]
- Stainless Steel Sheets[1]
- Steel Sheets[3]
- Silicon Steel[1]
- Bathroom Sinks[1]
- Shower Rooms[1]
- Towel Racks[1]
- Kitchen Cabinets[3]
- Mobile Phone Housings[1]
- Zinc[1]
- Other Accessories[1]
- Contact Person : Ms. manager Project
- Company Name : Shanghai Building Material Corporation
- Tel : 0086-21-68760737
- Fax : 0086-21-50819492
- Address : Shanghai,shanghai,pudong
- Country/Region : China
- Zip : 200122
Diesel Generator Sets
Shanghai Metal Corporation is renowned for providing superb quality and assures the best performance of its products at all times.SMC's core business focuses on design, manufacture, supply, installation and after sales services with our highly trained and experienced technicians and engineers for diesel generator sets ranging from 7 KVA to 1500 KVA. SMC supply open and silent gensets, super silent gensets, high voltage genset, light tower, communication base station power, mobile power stations, shelters, base stations, power plants and arctic zones integrated communications devices.
Specifications of generator diesel :1 Engines: Perkins, Cummins, Mitsubishi, Doosan, MTU and Lovol engines coupled with Stamford, LeroySomer and Cedex alternators engines2 Series: 1)SMC-C SMC-CL SMC-CX 2)SMC-L SMC-LL SMC-LX 3)SMC-P SMC-PL SMC-PX 4)SMC-D SMC-DL SMC-DX 5)SMC-M SMC-MX 3 Frequency: 50HZ, Speed: 1500 RPM 60HZ, Speed: 1800RPM4 Prime Power: 7 KVA to 1500 KVA5 Standby Power:8KVA to 1650KVA6 Weight: 397Kg to 16950Kg7 Dimension L/W/H(mm):1410/715/1050 to 6560/2850/3350
Applications of generator diesel :1. Stationary installation2. Installation in buildings3. To supply important consumer during power failure4. Fields of Operation: 1)Industry 2)Hospitals 3)Shopping Malls 4)Office and Communication buildings 5)Public Buildings
Controller of generator diesel :Genunit1.0/Genunit2.0/Deepsea Controller/DSE7510 1) 128×64 graphic LCD2) True RMS measuring 3) Configuration of parameters by frontpanel push buttons or communication software 4) RS485,RS232,or USB port for remote communication5) Configurable fuel output energise to stop or energise to run.6) 7 Configurable inputs 7) 4 Configurable ouputs8) 2 Analogue inputs configurable for differentsenders for Oil pressure and Engine temperature 9) 2 Aux,configurable analogue inputsACCEX510a/550a1) Microcomputer control, digital technology2) Model seting by control panel3) LED indicator4) PC connection through RS485 port.5) All data readable and editable
Detailed Information for generator diesel :
1)Open genset:The special purpose of this type of gensets is the indoor usage. This gensets are driven by diesel engines which correspond to legal standards of emissions for stationary engines.
Pictures of generator diesel :
SBMC-C Series:1.Cummins engine coupled with Stamford2.Efficient intake system3.P/T fuel pump injection technology4.Electronic governor
Genset Model | SBMC-C | SBMC-CL | SBMC-CX | ||||
min | max | min | max | min | max | ||
SBMC-C44 | SBMC-C1375 | SBMC-CL44 | SBMC-CL1650 | SBMC-CX44 | SBMC-CX1650 | ||
Prime Power | KVA | 40 | 1250 | 40 | 1500 | 40 | 1500 |
KW | 32 | 1000 | 32 | 1200 | 32 | 1200 | |
standby power | KVA | 44 | 1375 | 44 | 1650 | 44 | 1650 |
KW | 35 | 1100 | 35 | 1320 | 35 | 1320 | |
Engine Model | 4BT3.9-G2 | KTA50-G3 | 4BT3.9-G2 | KTA50-G8 | 4BT3.9-G2 | KTA50-G8 | |
Cyl | 4L | 16V | 4L | 16V | 4L | 16V | |
Displacement(L) | 3.9 | 50.3 | 3.9 | 50.3 | 3.9 | 50.3 | |
Alternator | PI 144J | LVI634G | LSA43.2 S15 | LSA50.2L8 | CX224S1 | CX404M8 | |
Weight(Kg) | 837 | 8795 | 845 | 11408 | 837 | 11408 | |
Dimension(mm) | 1800*820*135 | 4220*1815*2310 | 1800*820*1355 | 4900*2220*2500 | 1800*820*1355 | 4900*2220*2500 |
SBMC-L Series:
Genset Model | SBMC-L | SBMC-L | SBMC-LX | ||||
min | max | min | max | min | max | ||
SBMC-L33 | SBMC-L150 | SBMC-LL33 | SBMC-LL150 | SBMC-LX33 | SBMC-LX150 | ||
Prime Power | KVA | 30 | 136 | 30 | 136 | 30 | 136 |
KW | 24 | 109 | 24 | 109 | 24 | 109 | |
standby power | KVA | 33 | 150 | 33 | 150 | 33 | 150 |
KW | 26 | 120 | 26 | 120 | 26 | 120 | |
Engine Model | 1003G | 1006TAG | 1003G | 1006TAG | 1003G | 1006TAG | |
Cyl | 3L | 6L | 3L | 6L | 3L | 6L | |
Displacement(L) | 2.99 | 5.99 | 2.99 | 5.99 | 2.99 | 5.99 | |
Alternator | PI 144G | UCI 274E | LSAP 42 D | LSAP 44 F | CX25 | CX112 | |
Weight(Kg) | 822 | 1504 | 822 | 1504 | 822 | 1504 | |
Dimension(mm) | 1650*770*1260 | 2320*880*1450 | 1650*770*1260 | 2320*880*1450 | 1650*770*1260 | 2320*880*1450 | |
Discription | Lovol engine coupled with Stamford alternator | Lovol engine coupled with Leroy Somer | Lovol engine coupled with Cedex alternator |
SBMC-P Series:1.Perkins engine coupled with Stamford/Leroy Somer/Faraday/Cedex alternator2.Low fuel consumption and noise 3.Emission meets the German TALuft standard4.Prevent condensation heater/current transformer for parallel operation (option)
Genset Model | SBMC-P | SMC-PL | SMC-PX | ||||
min | max | min | max | min | max | ||
SBMC-P10 | SBMC-P2250 | SBMC-PL10 | SBMC-PL2500 | SBMC-PX10 | SBMC-PX1650 | ||
Prime Power | KVA | 9 | 2058 | 9 | 2250 | 9 | 1500 |
KW | 7 | 1646 | 7 | 1800 | 7 | 1250 | |
standby power | KVA | 10 | 2250 | 10 | 2475 | 10 | 1650 |
KW | 8 | 1800 | 8 | 1980 | 8 | 1320 | |
Engine Model | 403D-11G | 4016TAG2A | 403D-11G | 4016-61TRG3 | 403D-11G | 4012-46TAG2A | |
Cyl | 3L | 16V | 3L | 16V | 3L | 12V | |
Displacement(L) | 1.1 | 61.1 | 1.1 | 61.1 | 1.1 | 45.8 | |
Alternator | PI044E | PI734F | LSA40 VS1 | LSA51.2 VL85 | CX164VS2 | CX404M8 | |
Weight(Kg) | 397 | 14361 | 402 | 16950 | 397 | 12428 | |
Dimension(mm) | 1320*700*1160 | 5665*2780*3464 | 1320*700*1160 | 6560*2850*3350 | 1320*700*1160 | 5000*2200*2530 | |
Discription | Perkins engine coupled with Stamford/Leroy Somer/Faraday/Cedex alternator | Perkins engine coupled with LeroyCedex alternator | Perkins engine coupled with Cedex alternator |
SBMC-M Series:1.Mitsubishi engine coupled with Stamford/Leroy Somer/Faraday/Cedex alternator2.Fast and reliable cool start 3.Mechanical governor
Genset Model | SBMC-M | SBMC-MX | |||||
SBMC-M7.5 | SBMC-M22 | SBMC-M33 | SBMC-MX7.5 | SBMC-MX22 | SBMC-MX33 | ||
Prime Power | KVA | 7 | 20 | 30 | 7 | 20 | 30 |
KW | 5 | 16 | 24 | 5 | 16 | 24 | |
standby power | KVA | 8 | 22 | 33 | 8 | 22 | 33 |
KW | 6 | 18 | 26 | 6 | 18 | 26 | |
Engine Model | L3E | S4Q2 | S4S | L3E | S4Q2 | S4S | |
Cyl | 3 | 4L | 4L | 3 | 4L | 4L | |
Displacement(L) | 1 | 2.5 | 3.3 | 1 | 2.5 | 3.3 | |
Alternator | BCI164A/PI044D | BCI184E/PI144D | PI144G | LSA40VS1 | LSA40 M5 | LSA42.2L9 | |
Weight(Kg) | 303 | 503 | 580 | 303 | 503 | 580 | |
Dimension(mm) | 1410*715*1050 | 1700*895*1150 | 1700*895*1150 | 1410*715*1050 | 1700*895*1150 | 1700*895*1150 |
SMC-D Series:
Genset Model | SMC-D | SMC-DL | SMC-DX | ||||
min | max | min | max | min | max | ||
SMC-D300 | SMC-D740 | SMC-DL300 | SMC-DL750 | SMC-DX300 | SMC-DX740 | ||
Prime Power | KVA | 275 | 670 | 275 | 682 | 275 | 675 |
KW | 200 | 536 | 200 | 545 | 200 | 540 | |
standby power | KVA | 302 | 708 | 302 | 750 | 302 | 743 |
KW | 242 | 590 | 242 | 600 | 242 | 594 | |
Engine Model | P126TI | P222LE-Ⅱ | P126TI | P222LE-Ⅱ | P126TI | P222LE-Ⅱ | |
Cyl | 6L | 12L | 6L | 12L | 6L | 12L | |
Displacement(L) | 11.051 | 21.967 | 11 | 21.9 | 11 | 21.9 | |
Alternator | HCI444D | HC1544F | LSA46.2 L9 | LSA49.1 M6 | CX314M3 | CX354M7 | |
Weight(Kg) | 2359 | 3464 | 2359 | 3692 | 2359 | 3464 | |
Dimension(mm) | 3000*1115*1525 | 3400*1400*1850 | 3000*1115*1525 | 3400*1400*1850 | 3000*1115*1525 | 3400*1400*1850 | |
Discription | 1.DOOSAN engine coupled with Stamford/Leroy Somer/Faraday/Cedex alternator 2.Low fuel consumption and noise 3.Emission meets the German TALuft standard 4.Prevent condensation heater/current transformer for parallel operation (option) | 1.DOOSAN engine coupled with Leroy Somer alternator 2.Efficient intake system 3. P/T fuel pump injection technology 4.Electronic governor | 1.DOOSAN engine coupled with Cedex alternator 2.Efficient intake system 3. P/T fuel pump injection technology 4.Electronic governor |
2)Silent Type Generator Set: 1.Sound level meter is between 65 and 75 dB(A)@7m 2.New materials and advanced process, 3C ventilation system 3.Residential muffler, reducing noise substantially4.With 3 access doors and 1 observation window
Series | Output | Dimension L*W*H(mm) | Weight | Noise Index bd(A)@7m |
SMC-M Series | 7.5/11.5/16KVA | 1851*741*1324 | 250 | 68 |
22/33KVA | 2112*902*1490 | 306 | 71 | |
SBMC-P Series | 10/15/22KVA | 1856*826*1415 | 245 | 76 |
33/50/66KVA | 2396*1056*1723 | 389 | 75 | |
88/110/KVA | 3146*1056*1850 | 622 | 76.9 | |
150/165/200KVA | 3436*1156*1968 | 750 | 76.9 | |
220/250/275KVA | 3686*1256*2068 | 950 | 82.4 | |
385/440KVA | 4706*1356*2537 | 1125 | 82.4 | |
500/550KVA | 5206*1506*2686 | 1250 | 82.5 | |
650/700KVA | 5306*1706*2935 | 1295 | 82.5 | |
SBMC-C Series | 33/40/55/66KVA | 2396*1056*1723 | 389 | 78 |
80/93/110/125KVA | 3146*1056*1850 | 622 | 76 | |
145/175/200KVA | 3436*1156*1968 | 750 | 78 | |
220/250/275KVA | 3686*1256*2068 | 950 | 78 | |
330/345/385KVA | 4366*1306*2404 | 1125 | 80 | |
450KVA | 4706*1356*2537 | 1175 | 80 | |
510/550KVA | 5206*1506*2686 | 1250 | 82.4 |
3)Trailer Moblie Power Station: 1.Specializing design for mobile and out-door application. 2.Single-axis and double-axis structures. 3.Equipped with springs and double-break device for moving safely. 4.Rainproof and soundproof canopy, without access door or observation window 5.Support horizontal adjustment on the slope6.Optional installation of cable winch and terminal box
4)Silent Container Shield Genset : 1. Adopt standard 20 feet or 40 feet container modification, make the generator set more flexibility 2. Equipped with sound absorbing cotton and perforated metal.3. Built-in industrial muffler. 4. Sound level meter is between 70 and 80 dB(A)@7m 5. Controller cabinet, power supply system and lighting system, easy maintenance6. High corrosion resistance
Standard Container | ||||
Series | Output | Dimension | Weight | Mute Model |
SBMC-C Series | 625KVA/715KVA | 6058*2438*2591 | 2230 | 20 feet container |
825KVA/1250KVA | 12192*2438*2896 | 4020 | 40 feet heightening container | |
SBMC-P Series | 650KVA/700KVA | 6058*2438*2591 | 2230 | 20 feet container |
800KVA/880KVA | 12192*2438*2591 | 3780 | 20 feet container | |
1100KVA/1485KVA | 12192*2438*2896 | 4020 | 40 feet heightening container | |
Cuboid-shaped Units | ||||
Series | Output | Dimension | Weight | Noise Index bB(A)@7m |
SBMC-C Series | 825KVA | 7000*2438*2700 | 3250 | 85 |
1000KVA/12502KVA | 8500*3200*3370 | 5600 | 87 | |
SBMC-P Series | 800KVA/880KVA | 7000*2438*2700 | 3250 | 85 |
1100KVA/1880KVA | 8500*3200*3370 | 5600 | 87 |
5)Stackable Canopy Type: 1. Optimized and compact design 2. Space-saving and cost-effective 3. Applied to generator set up to 20KVA prime power
6)Mobile Power Station Description: 1.Maintaining shape and structure of the vehicle 2.Anti-vibration and heat insulation between vehicle chassis and power set 3.Noise reduction in compliance with the environment requirement4.Options for cable bracket or capstan 5.AC light system 6.Options for mechanical or hydraulic supporting device under vehicle chassis
Diesel Generator Sets